Surge arrester Type 1+2 (B+C) 4P 50kA 1.2kV SPD MOV TN-S/TT network contact SPA931 HAGER

Availability: In stock (large quantity)
Delivered within: 10 Business days
Delivery: The price does not include any possible payment costs check the delivery methods
Weight: 0.64 kg
Price / pcs.: £161.92 161.92
excl. shipping costs




quantity pcs.
Total:

product unavailable

add to wish list
* - Field mandatory
Visa Mastercard Google Pay Apple Pay PayPal Bank Transfer
Rating: 5
Vendor: HAGER
Product code: GPV-401-101

Description

Surge arrester Type 1+2 (B+C) 4P 50kA 1.2kV SPD MOV TN-S/TT network contact SPA931 HAGER

Surge arrester Type 1+2 (B+C) 4P 50kA 1.2kV SPD MOV TN-S/TT network contact SPA931 by HAGER also known as a lightning arrester, is designed to protect electrical installations from surges. This device is based on spark gaps and/or varistors, which consist of a base and an insert containing a protective element.

Its function is to limit the voltage pulse caused by a direct or near lightning strike on a power line. In order to ensure full protection, a three-stage surge protection system is used when supplying power to facilities, consisting of type 1, 2 and 3 surge arresters (otherwise known as B, C, D), which must be installed in cascade.

Specification

Manufacturer
HAGER
For the network
TN-S/TT
Protector class
B+C (Type 1+2)
Number of poles
4
Nominal discharge current (In)
50kA
Voltage level of protection
230 V
Maximum permissible operating voltage
335 V
Frequency of operation
50 / 60 Hz
IP degree of protection
IP20
Mounting method
Fixed installation to bus: TS 35
Series and type
SPD B+C T1+T2 MOV 4P surge arrester TN-S/TT network Iimp=50 kA In=50kA Up<1,2kV contact SPA931 HAGER
Number of modules
4
Optical signaling device
Yes
Rated switching voltage Ue (AC)
240 / 415 V
Maximum permanent operating voltage Uc
335 V
Voltage protection level Up
1.2 kV
Degree of protection Up L-PE / N-PE IEC 61643-11
1.2 kV
Degree of protection Up N-PE according to IEC61643-11
1.7 kV
Fuse
160 A
Dimensions
77.5 x 89.8 x 71.2 mm
Switching cross section of SSK input, with flexible conductor
0.4 / 1.5 mm²
Type of network
TT/TN-S
Mounting
TS rail
Approvals
KEMA
Tests according to EN 61643-11
T1 + T2
European Directive WEEE
Applies to

Available Configuration

Product code
Catalog no.
EAN
Model
GPV-401-101
next arrow image
SPA931/HAG
3250615515186
SPA931

Technical data

Application AC (mains)
Surge Protector Type (SPD Class) T1+T2 (B+C)
Rated Voltage [V] 275V AC
Number of poles 4P
Lightning Current (Iimp/In) [kA] 50 kA
Brand HAGER
Protection Level (Up) [kV] 1,2 kV

Safety

Shipping costs The price does not include any possible payment costs